Loader

Yorco Horizontal Laminar Air Flow Cabinets Overview
Improved Version Model

YORCO Horizontal Laminar Air Flow Cabinets are of International quality and are considered top-of-the-line by it’s very large number of regular users. YORCO Horizontal Laminar Air Flow Cabinet offers a combination of cabinet design and filtration systems to protect the work specimen from biological particulates. Horizontal Laminar Air Flow Cabinet with a constant face velocity airflow creates a performance envelope within and throughout the work surface to minimize or eliminate contamination.

Ideal for microbiological manipulations, tissue culture, sterility testing, research work & for general dry-processing work etc. Provides a comfortable ‘sit down’ working position for the operators.

High Performance Airflow :
The Horizontal Laminar Air Flow cabinet design regulates air velocity through latest Minipleat HEPA Filters and apportions the horizontal air flow across the work surface to create a containment zone. Cabinet surfaces are Aerodynamically shaped.

Ease of Use:
An ergonomic 10o sloped front improves comfort. Uniform interior lighting optimizes human interface.

High Capacity Filtration:
The Supply Minipleat HEPA Filter in extruded frame is designed to capture particulates with 99.97% efficiency for 0.3 microns. A closed cell peripheral gasket surrounds the filter housing to prevent particulate bypass and escape to the work area or laboratory. Pre filter is also in extruded Aluminum frame and of 90% efficiency at 10 microns is washable and cleanable.

Total Protection:
Specialized airflow system disperses air evenly over the supply Minipleat HEPA Filter, and eliminates potential leaks.

Simplified Controls:
The Microprocessor Controller is available in ‘Ex’ models only for continuous supervision of all cabinet functions, with universal icon touchpad buttons, simplified, one-handed access to On/Off and alarm monitoring system.

Construction:
CRCA Sheets are germicidal anti-microbial Powder Coated after 7-Tank Phosphating process for ultra long life and scratch resistance. All manufacturing is done on CNC machines. Sheet thickness is 1.2mm (18G) Std. However, 1.6mm (16G), 2mm (14G) are optional.

Exterior SS-304 / 316 / 316L is optional. Interior and Work Table are SS-304 Std.

icon

Vertical Laminar Air Flow Cabinet YSI-189

YORCO Vertical Laminar Air Flow Cabinets are of International quality and are considered top-of-the-line by it’s very large number of regular users. YORCO Vertical Laminar Air Flow Cabinet offers a combination of cabinet design and filtration systems to protect the work specimen from biological particulates. Vertical Laminar Air Flow Cabinet with a constant face velocity airflow creates a performance envelope within and throughout the work surface to minimize or eliminate contamination.
Ideal for microbiological manipulations, tissue culture, sterility testing, research work & for general dry-processing work etc. Provides a comfortable ‘sit down’ working position for the operators.
High Performance Airflow
The Vertical Laminar Air Flow cabinet design regulates air velocity through latest Minipleat HEPA Filters and apportions the vertical air flow across the work surface to create a containment zone. Cabinet surfaces are Aerodynamically shaped.

Ease of Use
An ergonomic 10o sloped front improves comfort. Uniform interior lighting optimizes human interface.

High Capacity Filtration
The Supply Minipleat HEPA Filter in extruded frame is designed to capture particulates with 99.97% efficiency for 0.3 microns. A closed cell peripheral gasket surrounds the filter housing to prevent particulate bypass and escape to the work area or laboratory. Pre filter is also in extruded Aluminum frame and of 90% efficiency at 10 microns is washable and cleanable.

Total Protection
Specialized airflow system disperses air evenly over the supply Minipleat HEPA Filter, and eliminates potential leaks.

Simplified Controls
The Microprocessor Controller is available in ‘Ex’ models only for continuous supervision of all cabinet functions, with universal icon touchpad buttons, simplified, one-handed access to On/Off and alarm monitoring system.

Construction
CRCA Sheets are germicidal anti-microbial Powder Coated after 7-Tank Phosphating process for ultra long life and scratch resistance. All manufacturing is done on CNC machines. Sheet thickness is 1.2mm (18G) Std. However, 1.6mm (16G), 2mm (14G) are optional. Exterior SS-304 / 316 / 316L is optional.

Salient Features :

  • Low Overall height of the upper structure increases leg room
  • Stable, self-supporting under carriage with adjustable leveling screws
  • Construction is of complete Body made of S.S. 304 as per GMP Std.
  • Workstation has a large surface area
  • Seamlessly welded basin measuring 400mm x 350mm x 165mm
  • Built in U.V. Germicidal Light
  • Exhaust duct flange
  • Stable, perforated S.S. 304 working plate (Optional)
  • Formalin dispensing tank with sieve insert (Optional)
  • Poly Ethylene cutting table board (Optional)
icon icon

Technical Specifications YSI-188 & YSI 189 Model :

  • Air Cleanliness in working area : Less than 3.5 Particles/Liter of 0.3 um and larger meeting ISO 14644-1, (Equivalent to Class 100 of US Fed Std 209 E)
  • Main Filters : HEPA Minipleat (ULPA Filter optional)
  • Minipleat HEPA Filters Efficiency : Rated for min. 99.97% efficiency of 0.3 microns’ particle size (99.99% & 99.999%, efficiency on request)
  • Pre-Filters able from front : Low pressure drop, 90% efficiency, 10 microns, washable, access
  • Air Velocity : 0.35 – 0.50 m/sec. 6” from filter face.
  • Minihelic filter pressure monitor : To monitor supply Minipleat HEPA / ULPA & pre-filters. (Magnehelic Gauge is optional)
  • UV sterilization : In work chamber, Emission in the germicidal Band UV-C 254 nm
  • Pressure Differential : Less than 15 mm Wc
  • Light Intensity on Work Table Avg. : >800 Lux
  • UV Light Intensity on Work Table Avg. : 40 microwatt / cm2
  • Half speed control : For idling period
  • Noise Level : < 60dbA at operator level
  • Inter lock : (i) UV / fluorescent lights/Door (ii) Air Flow/Sash (Flow stops with sash closed
  • Motors / Blowers : Double shaft, balanced, low vibration, 1/4 / 1/5 hp with RPM 1400 approx.
  • Power : 220-240 VAC/50Hz 1 Phase
icon icon

Yorco Laminar Flow Wall Module

Model HL-22 HL-32 HL-42 HL-62 HL-82
Work Area 2'x2'x2' 3'x2'x2' 4'x2'x2' 6'x2'x2' 8'x2'x2'
Size of HEPA Filter 2'x2'x3" 3'x2'x3" 4'x2'x3" 3'x2'x3" 4'x2'x3"
No. of HEPA Filter 2 1 1 2 2
No. of Pre – Filter 1 2 2 3 4
Illumination 1x20 w 1x20 w 2x40 w 2x40 w 4x40 w

icon